Bus duct comparison of the two technologies bus duct is defined in the nec 368. Duct board products are available with coated or faced airstream surfaces. The purpose of this chapter is to provide technical data on numerous bus conductor shapes and alloys as well as answers to basic questions on design and joining. Easily disconnected and connected when machines are moved. A simplified method of calculating busbar inductance and. Why dont they pickup the calculated bus fault current. Calculation of esdd02006 system fault levels issue no. Lowvelocity ductwork design is very important for energy efficiency in air distribution systems. Inthe power stations the generator voltages vary from 12 kv to 24kv whereas auxiliary supply voltages are 3. These limits should not be used for cables subjected to pulling tensions during installation. Calculate size of bus bar having following details bus bar current details.
Labor cost installation labor costs for bus duct systems can be less than labor costs for cable bus. Busbars may be enclosed in a metal housing, in the form of bus duct or busway, segregatedphase bus, or isolatedphase bus. The shorter the duct runs are, the lower the resistance to air flow and the lower the heat gains and heat losses will be. Advances in cable technologies, as well as the expense of repairing sensitive cable materials like fiber optic. Terminations less costly than bus duct entry provision. Ebus duct rated 49 ka rms symmetrical 2 seconds 1 all phase conductors above 635 v are fully insulated with epoxy insulation for the rated maximum voltage. Knowing required ampacity, determine possible bus bar dimensions from the table.
Copper or aluminum is used for the conductor of bus duct that be insulated and enclosed completely for protection against mechanical damage and dust accumulation. Powell is the premier designer and manufacturer of isolated phase bus, nonsegregated and segregated phase bus, cable bus and bus accessories in the united states. Read round duct diameter inches and friction loss per 100 of duct. Installation of delta unibus isolated phase bus duct system. Refurbishment of isolated phase bus that was damaged by others prior to installation. Magicad ventilation also offers a large selection of builtin calculations, such as flow summation, sizing, balancing, sound calculation. Cable tray, cable bus, wire mesh cable trays mp husky. Busbars may be connected to each other and to electrical apparatus by bolted, clamp, or welded connections. These products permit rigorous cleaning of the duct surface where dust has been allowed to collect in the duct due to lack of.
Rating 415v, 50hz ranging from 3200 amps to 5000 amps csegregated phase bus duct. Highvelocity hv duct systems are characterized by air velocities in the range of 2500 to 3500 fpm. The file contains 121 pages and is free to view, download or print. For use as drop cable from overhead bus duct to floor machines. When sizing busbars the designer only needs to make calcu. Karl s bogha electrical substation engineering and practice s.
You can then calculate bus bar rating based on the total connected load supplied by the bus bar and rate you bus. Unit 1 and unit 2 isolated phase bus duct welding and installation. Abus duct system is an effective method of distributing power to your. Sizing busbars the busbar constitutes the real backbone of any distribution assembly. Hvac load calculation check least based on the airah handbook. Resistant to oil, grease, acids, cutting fluids and mechanical abuse. Calculation of temperature rise in gas insulated busbar by. Bus duct should always be placed on the floor horizontally and, wooden battens or forms are placed underneath the busduct.
Air flow problems have plagued the hvac industry for years. Refer to uangyihtech flanges system section for adapters, drains and test port aw end available. These are hollow because flow of the high current exhibits small amount of current passing through the middle of conductor due to skin effect. Duct and conduit 473 chapter 14 duct and conduit introduction the general purpose of conduit, or duct, is to provide a clear, protected pathway for a cable, or for smaller conduits, sometimes called innerducts. This document was uploaded by user and they confirmed that they have the permission to share it. Ventilation systems design and calculations air renewal rates for premises in general recommended number of renewalshour, depending on the type of premises din 1946 standard. Flexible duct work must be stretched tightly for maximum air flow. Weight calculator standard conversion factors inch 25. In particular, the characteristics of a pair of busbars, and the use of the. Rated voltage 415v,50hz, desire maximum current rating of bus bar 630amp. This method is based on the partial inductance theory.
Ge industrial solutions metal enclosed nonsegregated bus. Ive run a 3 phase short circuit study but i have protective devices in my tcc drawing that still have isc amps of 200,000a. Free spreadsheet for hvac systems heating and cooling load estimation. Bus bars are thick metal connectors, usually of aluminium, whichcarry. Enter duct airflow cfm, duct velocity fpm, duct length and the number of bends. One disadvantage to locating the air handler in the attic. Home technical articles standards and applications of medium voltage bus duct bus duct is used for the effective and efficient supply of electricity in mostly industrial locations. The bus duct is designed, manufactured, and tested in accordance with ansiieee standard c37. There may be an additional voltage drop due to the inductance of the bar.
Thus, by using the above formula and table, we can easily select. Calculate the pressure loss of the duct fitting in a 600mm w x 200mm h duct. A numerical method for current density determination in threephase. Isolated phase bus ducts systems are vital components in power plants that are often overlooked.
Apr 03, 2016 readbag users suggest that qatarkahramaaregulations. Download ashrae heat load calculation excel sheet xls. It is used as an alternate means for conducting electricity to cable bus and power cables. From the point of view of the transmission reliability, busduct. Calculation of temperature rise in gas insulated busbar by coupled magnetothermalfluid analysis article in journal of electrical engineering and technology 44 december 2009 with 184 reads. Paying attention to certain details of bus duct projects will ensure troublefree service. Pdf recent progresses in busducts design researchgate. Power cable installation guide figure f5 multiple sheaves figure f6 sheave arrangements for feeding into cable tray training radius the training radius is the final positioning of cable ends after the cable has been placed in the raceway. With magicads automated design tools, even demanding duct routing solutions are easy to make.
Heat conduction and thermal resistance for steady state conditions and one dimensional heat transfer, the heat q. Bus ductsintroductionbus ducts or bus bars are used to carry very high current betweenthe generator and associated transformers, in the. Never locate ducts at the end of the trunk line run. Put your presentation title or confidentiality info here. Nonsegregated phase bus duct technical data td01702001e effective. Busduct is a system of distributing electric power using copper or aluminium busbars with. Pdf in this paper, a 3d eddycurrent field model for calculating the eddy current losses in an air insulated bus duct system aibds is. You should be able to get the voltage drop information from the bus duct manufacturer, or would would need to know the area and material of the bus to do your own calculation. Duct and conduit 473 chapter 14 duct and conduit introduction the general purpose of conduit, or duct, is to provide a clear, protected pathway for a cable, or for smaller conduits, sometimes called. In electric power distribution, a bus duct also called busway, is a sheet metal duct containing either copper or aluminium busbars for the purpose of conducting a substantial current of electricity.
A cover used to close off the bus duct entrance hole left in a transformer when it is removed or replaced. Abb low voltage and medium voltage busducts are safe, compact, flexible, reliable and efficient solutions for electrical power distribution. It is an alternative means of conducting electricity to power cables or cable bus. Recommended practices for designing and installing copper building wire systems cda cwis committee december 3, 20 developed by the. Bus drop cable pvc insulation pvc jacket applications. Recent progresses in busducts design article pdf available in compel international journal of computations and mathematics in electrical 351. You can then calculate bus bar rating based on the total connected load supplied by the bus bar and rate you bus bar based on percentages of full load current of connected load. Abus duct system is an effective method of distributing power to your switchgear and various loads.
Lowvelocity design will lead to larger duct sizes, but it may be worth since, doubling of duct diameter. During the installation, inspect the bus bar run for straightness in all planes and make any adjustment necessary for good alignment. Installed quickly without use of conduit for fixed or temporary power. And the enclosure size is where the cable bus advantage begins to pull away from the pack, where the maximum size for cable bus, so far, has been 26 inches wide by 12 inches high. Formoplastic range of bus ducts features our range of bus ducts optional features aconventional non segregated phase bus ducts. Cable bus systems are also very competitive to 600 volt bus duct systems as well. There is a gener al application section that applies to all types.
Mdy busduct system a reliable and safe solution for power. Duct design quick introduction duct sizing tools and methods recommended duct velocities and noise effects. Use insulated duct or duct board in unheated spaces. You need to determine the faul level of the systems and full load current from the customer to determine the cb rating. Recommended practices for designing and installing copper. More costly than cabl bus, to within 8 on top of cell or the duct including lugs and stress cone more cables to terminate. Standards and applications of medium voltage bus duct. Busbars may be enclosed in a metal housing, in the form of bus duct or. This plate bolts into the same bolt holes used for the bus duct entrance termination box and can be installed locally so that the transformer can be reused without sending it to emeryville to have the opening covered code 180203. Calculating bus duct voltage drop mike holts forum. Less costly than bus duct entry termination box must have bus risers provides all cable termination hardware provision. Busduct is a sheet metal duct with aluminium or copper bus bars, and used as a reliable link for transferring power from one equipment to other at desired voltage levels. Tables 4 and 5 summarize the estimated values for two.
Table gives bus bar cross section which will probably be large enough for ampacities within each range. Heat conduction and thermal resistance for steady state conditions and one dimensional heat transfer, the heat q conducted through a plane wall is given by. Method of statement for installation of power busbar method. This manual will be divided into several sections each section pertaining to a specific line of bus duct com plete with all of the dimensions, voltage drop curves, and characteristics. The standard produces fault current results for an unloaded network, that is the results do not include load current and the prefault. Pdf calculations of eddy current, fluid, and thermal fields in an. And for a comparable rated bus duct, that size is usually up to 36 inches by 18. Eliminates any faults caused by moisture in the bus duct protect your bus duct systems and your staff with a retrofitted dry air condensation control system from azz to effectively prevent condensation and ensure safe, reliable bus system operation.
Bus ductsintroductionbus ducts or bus bars are used to carry very high current betweenthe generator and associated transformers, in the power stations. These isophase bus duct systems are the only critical components within the plant that have no redundancy and no quick replacement solutions. And cables in tray, if you go up to 5,000 amps, you will end up with multiple tray runs. Download bus duct voltage drop calculation pdf free. We are ready to custom engineer your utility, cogeneration, petrochemical or heavy industrial application with a complete range of bus duct products, systems and services. Hvac cooling load calculations and principles sensible heat gain is the energy added to the space by conduction, convection andor radiation.
Isophase bus condition assessment doble engineering company. Calculation of induced current in bus duct shell is a fundamental problem in determining the exact bus duct losses, and it needs an accurate analysis of the plan, and to determine it, it is possible to use. Calculation of air volume to exhaust correction factors according to the type of installation chart 2 type of installation multiplication factor wallmounted hood 1. Condensation control for bus duct controlling moisture to maintain optimal bus. Ge industrial solutions metal enclosed nonsegregated bus duct description nonsegregated phase bus duct is designed for interconnecting groups of metalenclosed or metal clad switchgear, power transformers or other related equipment. Always stagger takeoff ducts by 12 to maintain pressure. Rating 415v, 50hz ranging from 800 amps to 3200 amps blow reactance interleaved bus ducts. Air duct calculator duct velocity duct airflow fpm cfm duct diameter round inches of water inches friction loss per 100 of duct flexible duct friction loss calculator sheet metal duct friction loss calculator duct diameter approximate dynamic loss coefficients duct length feet friction loss 2. Flow of air is caused as a result of pressure differential between two points.